 |
| Volume 3, Number 6, Article 3, Pages 423-431 |
doi:10.1167/3.6.3 |
http://journalofvision.org/3/6/3/ |
ISSN 1534-7362 |
Temporal dynamics of early light adaptation
Joel Pokorny |
Visual Science Laboratories, University of ChicagoChicago, IL, USA |
|
Vincent C. W. Sun |
Visual Science Laboratories, University of ChicagoChicago, IL, USA |
|
Vivianne C. Smith |
Visual Science Laboratories, University of ChicagoChicago, IL, USA |
|
Abstract
This study investigated two aspects of visual sensitivity to a change in light level. The first experiment examined the time course of sensitivity to a small amplitude 1-s contrast pedestal presented on a 163-td pedestal within a 115-td surround. The largest contrast pedestal was an 8% contrast change that changed the steady pedestal threshold by only 0.03 log unit. Thresholds increased by 0.6 log unit or more at both onset and offset, with a return to baseline within 100 ms. The increment and decrement thresholds showed different time courses. Increment thresholds were raised before pedestal onset and decrement thresholds were raised before pedestal offset. These data were interpreted to show that increment thresholds measured at onset and offset of a contrast pedestal accessed on-pathways and decrement thresholds accessed off-pathways. In the second experiment, we examined the time course of sensitivity using a Crawford paradigm. Observers were dark-adapted and sensitivity was measured before, during, and after a 0.5-s, 68-td pulse. Test stimuli were slightly biased in chromaticity and the observer reported the presence and the hue appearance of the test, allowing separate estimates of detection and hue identification. Thresholds increased during the pulse but showed only a minimal overshoot. The test sensitivity for detection was poorer than for hue identification in the dark, but detection and identification were similar during the pulse. These data suggest that thresholds during sizable luminance pulses are determined in the PC-pathway.
 |
|
History
Received February 7, 2003; published July 24, 2003
Citation
Pokorny, J., Sun, V. C. W., & Smith, V. C. (2003). Temporal dynamics of early light adaptation.
Journal of Vision, 3(6):3, 423-431,
http://journalofvision.org/3/6/3/,
doi:10.1167/3.6.3.
Keywords
contrast saturation, dynamics, Crawford paradigm
for related articles by these authors
for papers that cite this paper |
In 1947, Crawford (1947) published research that was
destined to become a classic contribution to visual science. He was interested
in the momentary blinding effect of artillery fire on dark nights. He used a
12° “conditioning” field of 0.5 s, on which was measured an
increment threshold using a small (0.5°), brief (10 ms) test. The test was
presented at a series of delays relative to the conditioning field onset.
Thresholds were higher during the conditioning field, showing an overshoot at
onset and offset, with some recovery during the conditioning pulse period. The
overshoot showed a rapid recovery within 100 ms with further recovery during the
0.5-sec conditioning period. The results showed an unexpected finding. The
threshold started to increase before the physical onset of the conditioning
field. Crawford attributed this result to the fact that the intense conditioning
flash showed a faster neural response than the threshold responses measured in
the dark. A similar phenomenon occurred at offset. The offset effect was
subsequently investigated more fully by Baker
(1953).
The Crawford data suggested that multiple mechanisms
were involved in thresholds measured at the onset and offset of a light stimulus
or when thresholds were measured on briefly pulsed backgrounds ( Alpern, Rushton, & Torii, 1970). These
mechanisms became a focus of interest in the 1970s and 1980s, with development
of a technique called the “probe-flash” paradigm. In a prototypical
probe-flash experiment ( Hood, Ilves, Maurer,
Wandell, & Buckingham, 1978), the observer viewed an 8° steady
background of fixed retinal illuminance. A 40' circular flash was presented for
a 0.5-s period and thresholds were measured for a 2' probe of 10 ms. These
experiments yielded a variety of effects, including cone saturation ( Hood et al., 1978), multiplicative and
subtractive neural adaptation ( Hayhoe,
Benimoff, & Hood, 1987), and the activity of multiple postreceptoral
pathways ( Finkelstein & Hood,
1981). Saturation measured in these studies occurred for very high flash
intensities (over 10,000 td) with the probe presented at 250 ms after flash
onset. This saturation was attributed to the cone receptor response. When the
probe was presented at flash onset, spectral sensitivity suggested activity in a
spectral opponent channel.
Saturation is a characteristic of all neurons. The
contrast transfer function of retinal ganglion cells shows contrast saturation
at high contrasts ( Shapley & Victor,
1978). In the primate, MC-pathway retinal ganglion cells show saturation
with achromatic contrast pulses of less than 10% and PC-pathway cells show a
more linear contrast response ( Kaplan &
Shapley, 1986). Pokorny and Smith
(1997) suggested that such contrast saturation responses can be measured in
human psychophysical studies.
The goal of this work was to evaluate two aspects of
early light adaptation. First, we evaluated recovery from a contrast pedestal
that was associated with only minor neural multiplicative or subtractive change.
This study used the Pedestal-Δ-Pedestal Paradigm that was described in Pokorny and Smith (1997). In a second
experiment, we returned to the original Crawford paradigm that used a large
pedestal step from darkness. We incorporated a design using chromatic pulses and
requiring one of three responses: “not seen,” “red,” or
“green.” The test stimuli were slightly biased in chromaticity, and
the observer reported the presence and the hue appearance of the test, allowing
separate estimates of detection and hue identification. Four interleaved
staircases were run concurrently; two (one for each chromaticity) reversed on
either “either hue,” and the other two required a correct hue
response. Correct hue identification requires activity in the parvocellular
spectral opponent pathways and allows us to compare thresholds with those of the
original Crawford paradigm.
Apparatus and Calibration
The stimuli were generated by a Macintosh PowerPC
Computer with a 10-bit Radius video card, and were displayed on a Radius
PressView SR or a NEC MultiSync FE750 17" color monitor. The monitor refresh
rate was 75 Hz. The monitor system was operated by computer programs written in
C language and compiled by CodeWarrior (Metrowerks, Inc., 1996) software.
Observers responded using a mouse. The display image size of the monitor was
about 75% of the maximum display area. The maximum luminance was 60
cd/m 2. The luminance output of each phosphor was measured at 1024
radiance levels and look-up tables allowed linear luminance control. The
phosphor spectral distributions were measured with an Optronic Laboratories
spectroradiometer (754-O-PMT), and the chromaticities of the phosphors were used
to calculate the desired chromaticities in the Boynton and Kambe (1980) relative cone
troland space .
Two of the authors (CS and JP) and three individuals
(HK, LS, and IY) naive to the experimental design served as observers. IY
participated in both experiments. All observers had normal visual acuity (with
refractive correction if necessary) and normal color vision according to the
Neitz OT anomaloscope, the Farnsworth-Munsell 100-hue test, the Ishihara
pseudoisochromatic plates, and the Standard Pseudoisochromatic Plates II
test.
An adaptive staircase determined the test retinal
illuminance for each trial. In Experiment 1, a pair of staircases randomly
alternated was used to measure thresholds in both an increment direction and a
decrement direction. In Experiment 2, four staircases were randomly alternated
to measure detection and hue identification of two chromatic tests. At the start
of a staircase, an easily discriminable test contrast was present and on
succeeding trials the step size was halved until a criterion step of 0.025
log unit was reached. The criterion was
set in pilot studies to produce an efficient staircase, requiring about 60-70
trials. Once the criterion step size was reached, the staircases continued
without further change in step size using a reversal rule (specified below for
each experiment). Eight-to-ten reversals at the criterion step size were
measured for each staircase. The average contrast at which the last six
reversals occurred was taken as the estimate of the threshold contrast. The
entire protocol was repeated 3 times to give an average threshold.
Experiment 1: Pedestal-Δ-Pedestal
Experiment 1 employed the Pedestal-∆-Pedestal
Paradigm described in Pokorny and Smith
(1997). The rationale for the complicated pedestal-∆-pedestal design
was to separate the MC- and PC-pathway thresholds so that the characteristic
contrast discrimination response of the MC-pathway could be followed.
The stimuli consisted of four 1° squares arranged
as a four-square array with 0.07° gap separations. The test stimuli were
displayed in the center of the monitor with an 8° by 8° uniform
surround that also filled the gaps between the four squares. The display was
viewed binocularly with natural pupils at a distance of 1 m and the chromaticity
of the test and surround was metameric to the equal energy spectrum (EES)
(0.66457, 0.997; chromaticity specified in the Boynton & Kambe (1980) relative cone
troland space). The surround retinal illuminance was 115 td, and the four-square
array was presented continuously as a steady pedestal at 162 td. The test
stimulus was presented as an added four-square Δ-pedestal array during each
trial. A small square fixation target (4.36') in the monitor center provided a
fixation guide.
The observer first adapted for 2 min to a uniform
115-td display that included the fixation target followed by 1 min of adaptation
to the steady pedestal retinal illuminance. During each trial, the
Δ-pedestal was presented for 1,000 ms, and one of the four squares (the
target square) changed to the variable test luminance as a 26.67 pulse (two
refreshes) after a Δ-pedestal-to-pedestal delay. The next trial then
started after a 1-s inter-trial interval. The observer was instructed that one
square might appear brighter or darker than the other three and the task was to
identify the “odd” square. At the start of a trial, the fixation
target disappeared. The test square was selected randomly with equal probability
at each position. At the trial conclusion, the fixation target reappeared
together with a cursor. The observer used the mouse to place the cursor in the
stimulus position judged differently. A mouse click at this position stored the
result and reset the display for the next trial. No feedback was given. In
Experiment 1, the reversal rule for was set at 3-correct-2-incorrect.
There were two protocols. In the first, the time course
was examined with the Δ-pedestal fixed at 186 td. The delay of the test
pulse from the Δ-pedestal onset was varied from -106.67 ms to 1213.33 ms,
where negative values indicated that the test square was presented before the
presentation of the Δ-pedestal array. The delays were presented in separate
sessions. In the second protocol, three delays were examined: 0 ms, 26.7 ms, and
506.7 ms, and a series of seven Δ-pedestals was used at each delay. The
Δ-pedestals varied from 141 to 186 td. Each session included three or four
Δ-pedestals at a chosen delay. With zero delay, the protocol was similar to
Pokorny and Smith (1997).
Increment and decrement contrast discrimination
thresholds measured with the Δ-pedestal-to-test delays from -106.7 to
1213.3 ms are plotted in Figure 1 as a function
of the delay. The three panels show data of three observers. The dashed line
shows the average Δ-pedestal threshold measured in the second protocol.
Observers CS and IY showed minimal difference (< 0.1
log unit) in these thresholds but HK
was 0.2 log unit less sensitive in the
temporal paradigm and showed more scatter in thresholds. Thresholds rose at
Δ-pedestal onset, reached their maximum, and returned to near baseline
sensitivity within 100 ms. Thresholds then rose again at the Δ-pedestal
offset, and then returned to baseline within 100 ms. The time course for
increments and decrements differed subtly but consistently among observers. The
increment thresholds reached their first peak about 25 ms before Δ-pedestal
onset but their second peak coincided with Δ-pedestal offset. In
comparison, the decrement thresholds reached their first peak at Δ-pedestal
onset but their second peak occurred about 25 ms before the Δ-pedestal
offset.
Figure 1. The time
course of thresholds measured on a 1,000-ms contrast Δ-pedestal. Each panel
shows data of a different observer. Increment thresholds are shown by open
symbols and solid lines; decrement thresholds are shown by closed symbols and
dashed lines. The lines represent fits of contrast saturation functions with an
exponential time course. The horizontal line shows the average threshold
measured on the steady-state pedestal in a separate experiment.
The data could be described by modifying an equation to
describe contrast saturation in the MC-pathway ( Pokorny & Smith, 1997; Smith, Sun, & Pokorny, 2001). This
equation describes contrast discrimination as dictated by a product of the
threshold term, steady-state gain to the pedestal, and saturation to the
Δ-pedestal:
| LogΔI
=
Log[(Csat+|C|)2/{Csat
–
(KC)(Csat+|C|}]+Log(KIS), | (1) |
where
|C| represents the
absolute value of the Δ-Pedestal Weber contrast
(ΔP/IP),
Csat
represents the saturating contrast,
KC
represents the criterion increment firing rate (comparable to
δ/Rmax
of a single cell), and
K represents the
overall scaling constant. The overall scaling constant,
K,
incorporates threshold sensitivity and gain for the presumed MC-pathway.
We can incorporate time dependence by adding an exponential time constant at
onset and at offset to describe the recovery from
saturation:
| Log
ΔI = Log{[Csat+|C|
exp(-t/τ)]2/[Csat
-
(KC)(Csat+|C|
exp(–t/τ))]}+ Log {GP+(ΔG)[1-
exp(-t/τ))]}
+
Log(KIS), |
(2) |
where
GP
represents the gain term at 162td and
(Δ G)
represents the added gain (1.15 fold) caused by the 24-td Δ-pedestal. This
equation gives an instantaneous change in contrast at onset (or offset), which
recovers exponentially with time constant
τ.
The peak advances can be described by replacing
exp(–t
/
τ) by
exp(–(t+k)/t)
where k is a
constant.
The solid lines show fits of Equation (2) to the data of the three observers.
For these fits, we allow variation of
τ,
k,
Csat,
and K. The value of
τ varied from 23 - 40 ms. The
values of
k
varied from 17 – 30 ms. The advance was required to fit the
increment thresholds measured at Δ-pedestal onset and to fit the decrement
thresholds measured at Δ-pedestal offset. The values for
Csat,
were 0.12 – 0.14. These values are consistent with values for contrast
saturation in retinal ganglion cell data in the MC-pathway. In general, the
quality of the fits was good. The use of a single exponential implies that the
onset of saturation was instantaneous. However, data for early light adaptation
show a more gradual rise. This could be modeled if the pathways mediating
detection involved an average over cells with slightly varying time constants.
There was no expectation that the time constant of the gain change should match
the time constant of the contrast saturation. However, because the expected gain
change was so small, there was no rationale to adjust the time
constant.
Figures 2-4 show the results of varying contrast at three
fixed delays for the three observers. The upper panel shows data for increments
and the lower panel shows data for decrements. Also shown on the graphs are data
from the Steady-Pedestal Paradigms previously collected on all three observers
( Smith et al., 2001). The data were fit by
Equation (2). The
parameters t, k,
Csat,
were those used to fit the delay data. The scaling
K was varied to
account for day-to-day variability. Data were similar for all three observers.
There was a steep V-shape at 0 delay, flattening at 26.7-ms delay. The
thresholds at 506.7-ms delay corresponded well with the previous data from the
Steady Pedestal Paradigm ( Smith et al.,
2001). The three observers were well practiced, having participated in a
variety of contrast discrimination experiments over a one-year period. Their
thresholds were low. The smallest fixed Δ-pedestal was approximately twice
threshold. There was no indication of facilitation (dipper effect) or inhibition
(bumper effect) ( Bowen, 1997). The minimum
of the V-shape occurred primarily for the zero Δ-pedestal, although there
was some scatter among
observers.
Figure 2. The thresholds measured on a
1,000-ms Δ-pedestal at one of three fixed test delays, 0 (circles), 26.667
(squares), or 506.667 (triangles) ms. Increment thresholds are shown by open
symbols and solid lines; decrement thresholds are shown by closed symbols and
dashed lines. The lines represent fits of contrast saturation functions
described in the text. Data from previous steady-state experiments are shown for
comparison. The data are for observer HK.
Figure 3. The thresholds measured on a
1,000-ms Δ-pedestal at one of three fixed test delays, 0, 26.667, or
506.667 ms. The data are for observer CS. The data format is as for Figure 2.
Figure 4. The thresholds measured on a
1000-ms Δ-pedestal at one of three fixed test delays, 0, 26.667, or 506.667
ms. The data are for observer IY. The data format is as for Figure 2.
We designed Experiment 1 to constrain the thresholds to
the inferred MC-pathway. There were three critical aspects to the choice of
stimulus parameters. Based on the Pokorny and
Smith (1997) data, we chose (a) a short duration stimulus pulse to maximize
the difference in steady pedestal and pulsed pedestal thresholds, (b) a steady
pedestal level that produced a large difference between the inferred MC- and
PC-pathway sensitivities, and (c) a Δ-pedestal amplitude that resulted in
threshold retinal illuminances below the inferred PC-pathway threshold. The
experimental parameters gave us a 0.7-0.8
log unit window where the MC-pathway is
more sensitive than the PC-pathway. The data of Figures 1-4 are
consistent with threshold mediation in the MC-pathway at all durations.
The two protocols, varying delay at a fixed
Δ-pedestal or varying Δ-pedestal at a fixed delay, gave the same
picture of contrast saturation in the MC-pathway. In the first protocol, the
increment and decrement staircases yielded different time courses at onset and
offset. This phenomenon may be related to MC-pathway ganglion cell data. The
on-pathway saturates to an increment pedestal but is silenced by a decrement.
Conversely, the off-pathway saturates to a decrement pedestal but is silenced by
an increment. Recovery to a saturating pedestal is faster than recovery to a
pedestal that drives the membrane potential below the spike threshold ( Lee, Smith, & Pokorny, 1999). Our data are
consistent with this phenomenon. In the second protocol, we found a consistent
asymmetry between the increment and decrement thresholds. Increment thresholds
were steeper for decrement Δ-pedestals and decrement thresholds were
steeper for increment Δ-pedestals. This effect was consistent across
observers and agreed with the time course data of Figure 1. Since the saturation effect and its
recovery were advanced for increments measured at Δ-pedestal onset, the
increment thresholds are lower than decrement thresholds for positive delays
following onset. The reverse happened at Δ-pedestal offset. In the original
experiment ( Pokorny & Smith, 1977),
increment and decrement thresholds were averaged, thus the effect was not
noticed. A review of the raw data confirmed that the phenomenon was present. A
similar phenomenon was previously reported by Bowen (1997) using a cosine mask (pedestal in
our terminology) and a spatial test formed by a D6 waveform. We conclude that
when contrast discrimination is measured on a brief contrast step, or on the
rising or falling portions of a longer contrast step, increment thresholds
reflect activity in an on-pathway and decrement thresholds reflect activity in
an off-pathway.
Crawford (1947)
first reported that thresholds are elevated in advance of a conditioning
stimulus. He proposed either that the conditioning stimulus
“overtook” the flash between retina and brain, or that the
perceptual process was sufficiently long as to allow interference of test
perception by the conditioning stimulus. Subsequently, the phenomenon was termed
backward masking and attributed to interactions among fast and slow pathways. In
Experiment 1, we consider that our stimuli are processed within on- or
off-MC-pathway cells responding to a contrast-saturating pulse. We suggest that
the phenomenon might be caused by a contrast nonlinearity in the retina. Primate
MC-cells ( Benardete, Kaplan, & Knight,
1992; Kaplan & Benardete, 2001; Lee, Pokorny, Smith, Martin, & Valberg,
1990) and cat X- and Y- cells ( Shapley
& Victor, 1978, 1979; Victor, 1987, 1988) show a phase advance with contrast that
has been attributed to a retinal contrast gain control ( Victor, 1987, 1988). This effect is observed in pulse data
( Lee, Pokorny, Smith, & Kremers, 1994),
but is at most 8-12 msec. Our data show advances of 25 msec.
Experiment 2: The Crawford Paradigm Revisited
In Experiment 2, we replicated the Crawford (1947) experiment with chromatic
test stimuli superimposed on a white pedestal (conditioning field in the
Crawford terminology). The rationale for this protocol was to implement a hue
identification response, which presumably is mediated by the PC-pathway. Thus,
we could examine the form of Crawford early light adaptation in the
PC-pathway.
The test stimulus was a 0.5° circular spot
centered on a 12° diameter circular pedestal. The stimuli were viewed
through a 3-mm artificial pupil. The luminance of the pedestal was 9.6
cd/m 2, with chromaticity metameric to the EES (0.66457, 0.997;
chromaticity specified in the Boynton & Kambe, 1980, relative cone troland
space). This luminance corresponded to 68 trolands with the artificial pupil.
The light level was constrained by the light levels available on a CRT monitor,
and was lower than in Crawford’s experiment. The steady-state rise in
threshold was circa 1.4
log unit,
compared with a 2.2 log unit rise for
Crawford’s dimmest conditioning field. Three test stimuli were used: an
EES test with chromaticity coordinates (0.66457, 0.997), a
“greenish” test with chromaticity coordinates (0.640, 0.997) and a
“reddish” test with chromaticity coordinates (0.690, 0.997).
For thresholds measured on the dark background, a large
sheet of 0.3 neutral density filter (GamColor, Los Angeles, CA) was inserted in
front of the monitor screen. The pedestal retinal illuminance was doubled to
compensate for the filter. Two sets of four 12' dots provided a fixation guide
to the screen location in the dark periods. An inner set lay on the perimeter of
a 4° diameter circle; an outer set lay on the perimeter of a 12.2°
circle. The inner set provided fixation in the dark and was replaced by the
pedestal. The outer set remained visible for the whole protocol.
At the beginning of each experimental session,
observers viewed a dark screen with the fixation dots for 2 min. During each
trial, the pedestal was presented for 506.7 ms. The test stimulus was presented
as a brief pulse of 13.3 ms (one refresh) at the field center after a delay from
the onset of the conditioning field. The subsequent trial began 2 s following
the observer response. Thresholds were gathered for 20 test delays,
systematically sampled from -306 ms to 1396.6 ms, where negative values
indicated that the test was presented before the pedestal onset. Four delays
were interleaved in an experimental session. These were grouped so that the
thresholds determined in the dark and pedestal periods were measured in
different sessions.
In a control experiment, we compared detection
thresholds interleaving reddish and EES staircases. The reddish and greenish
stimuli were used in the main experiment. A multiple-judgment task was used to
measure thresholds for detection and chromatic identification in four separate
staircases for the reddish and greenish stimuli. After each trial, the observer
used game pad (Gravis 4211) switches to indicate one of three choices:
“reddish”, “greenish”, or “not seen.” Four
thresholds were measured, detection and identification of the reddish test
pulses, and detection and identification of the greenish test pulses. Thus, 16
staircases were run concurrently in each experimental session. For the
measurement of detection thresholds, the staircase followed a yes-no reversal
rule, and both the reddish and greenish responses were treated as yes. For the
measurement of chromatic identification thresholds, a 3-correct-1-incorrect
reversal rule was used, and only the accurate identification of the direction of
chromatic change was taken as a correct response.
We first established chromaticities that yielded
similar detection thresholds in the dark and on the pedestal for the greenish
and reddish stimuli. We next evaluated whether the chromatic detection data were
representative of detection of a chromatically neutral stimulus. Figure 5 compares threshold detection data for an
EES stimulus and the chromatically reddish stimulus (no chromatic identification
staircases were run for these conditions). There are no systematic differences
between thresholds for the EES and chromatic stimuli.
Figure 5. The time course of thresholds
measured on a 506-ms, 68-td achromatic pedestal. The panels show data of two
observers. Thresholds are shown for detection for a test light metameric to the
EES (black symbols) and a chromatic test light that appeared slightly
“reddish” (red symbols). The solid lines are exponential fits to the
recovery data.
The
data of the main experiment are displayed in Figure
6. Open symbols show the detection results and closed symbols show the hue
identification results; both are color coded by stimulus chromaticity. The tasks
yielded similar data for both observers. Following onset of the pedestal,
thresholds rose abruptly. Thresholds were highest about 50-100 ms following
onset and showed a slight recovery. Thresholds declined abruptly at stimulus
offset and reached baseline within 200 ms. The detection data were more
sensitive than the identification data in the dark with an average difference of
0.45 log unit. The detection data were
consistently more sensitive (about 0.08
log unit), though they had overlapping
standard deviations. The black lines show a fit of an exponential equation to
the recovery data. The time constant for recovery was 87 ms for JP and 125 ms
for IY and was similar for both detection and hue identification. This time
course is slower than for recovery from a contrast pedestal in Experiment 1
( c. 25 ms) but much
faster than recovery from a bleaching light
( c. 120
s).
Figure 6. The time course of thresholds
measured on a 506-ms, 68-td achromatic pedestal. The panels show data of two
observers. Thresholds are shown for detection and hue identification for a pair
of chromatic test lights, biased to appear slightly reddish or greenish.
Detection thresholds are indicated by open symbols; hue identification
thresholds are shown by closed symbols. Red squares indicate the reddish biased
test chromaticity and green circles indicate the greenish biased test
chromaticity. The solid lines are exponential fits to the recovery data.
In Experiment 2, we were interested in distinguishing
pathway activity in the Crawford paradigm and compared detection data with hue
identification data in concurrently run detection/identification tasks. The hue
identification task provided an index of PC-pathway sensitivity since there is
no evidence of the MC-pathway providing a redness-greenness code. We employed
stimuli with subtle chromaticity differences; larger or smaller chromaticity
differences between the greenish and reddish stimuli would have resulted in
higher or lower estimated PC-pathway sensitivities. Additionally, the different
decision rules used to govern staircase reversals for the two tasks affected the
relative sensitivities to a small degree. Thus, while we expected the hue
identification function to characterize the time course of PC-mediated
detection, it could not offer a guide to absolute sensitivity.
We interpret the detection data in the dark as
reflecting MC-pathway mediation (the data in Figure
5 showed that detection was the same for one of the chromatic stimuli and an
achromatic appearing stimulus). There was a
0.4- log unit cone photochromatic
interval. At pedestal onset and offset, we saw no overshoots as would be
expected of the MC-pathway and demonstrated in Experiment 1. This result leads
us to conclude that thresholds within +/- 25 ms of onset and offset were
mediated by the PC-pathway.
Based on earlier work, we expected that the MC-pathway
might be more sensitive during the mid-period of the 68-td pedestal; for a
similarly sized stimulus, observer IY showed an
~0.1- log unit MC-pathway advantage ( Smith et al, 2001; we do not have
corresponding data for observer JP). However, the parallel threshold functions
from the beginning to the end of the pedestal are consistent with PC-pathway
mediation of these detection data. The data with which we defined relative PC-
and MC-pathway sensitivities ( Pokorny &
Smith, 1997; Smith et al., 2001) were
gathered with gaps between the discrimination stimuli. Separating stimuli
impairs luminance discrimination ( Boynton,
Hayhoe, & MacLeod, 1977; Sharpe &
Wyszecki, 1976), but it is not possible from these studies to identify the
pathway mediating the discriminations.
The data showed a conspicuous difference from
Crawford’s classic data; there was no overshoot at pedestal onset/offset.
This is likely due to the lower retinal illuminance of the pedestal. Our
pedestal was about 10-fold lower than Crawford’s lowest conditioning
field. The rapid overshoot in the usual Crawford experiment probably represents
contrast saturation in both the PC- and MC-pathways.
The exponential recovery functions we fit to the
sensitivity recovery at pedestal offset for the two experiments have different
interpretations. For the Pedestal-Δ-Pedestal Paradigm, the very small step
in pedestal retinal illuminance is insufficient to result in a substantial
sensitivity change due to sensitivity regulation. This is evident from the small
differences in thresholds measured prior to the pedestal and after the pedestal
had been presented for 500 msec. Thus the 25-msec time constant represents the
recovery from contrast saturation. For the Crawford paradigm, there is a
substantial change in sensitivity during the pedestal. Here, the ~100-msec time
constant represents the time course of recovery of the mechanism involved in
sensitivity regulation.
National Eye Institute Research Grant EY00901 supported
this research. Publication was supported in part by an unrestricted grant to the
Department of Ophthalmology and Visual Science from Research to Prevent
Blindness. We thank our observers HK, LS, and IY for their patience, and Linda
Glennie for programming assistance. Commercial relationships: none.
1Present
Address: Department of Psychology, Fu Jen Catholic University, 510 Chung Cheng
Road, Hsinchuang, Taipei Hsien, Taiwan 24205.
Alpern, M., Rushton, W. A. H., & Torii, S. (1970).
Signals from cones.
Journal of Physiology
(London), 207, 463-475.[ PubMed]
Baker, H. D. (1953).
Instantaneous thresholds and early dark adaptation.
Journal of the Optical Society of America,
43, 798-803.
Benardete, E. A., Kaplan,
E., & Knight, B. W. (1992). Contrast gain control in the primate retina: P
cells are not X-like, some M cells are. Visual
Neuroscience, 8, 483-486.[ PubMed]
Bowen, R. W. (1997). Isolation
and interaction of ON and OFF pathways in human vision: Contrast discrimination
at pattern offset. Vision Research,
37(2), 185-198.[ PubMed]
Boynton, R. M., Hayhoe, M.
M., & MacLeod, D. I. A. (1977). The gap effect: Chromatic and achromatic
visual discrimination as affected by field separation.
Optica Acta, 24, 159-177.
Boynton,
R. M., & Kambe, N. (1980). Chromatic difference steps of moderate size
measured along theoretically critical axes.
Color Research and Application, 5,
13-23.
Crawford, B. H. (1947).
Visual adaptation in relation to brief conditioning stimuli.
Proceedings of the Royal Society, B,
134, 283-302.
Finkelstein, M. A.,
& Hood, D. C. (1981). Cone system saturation: More than one stage of
sensitivity loss. Vision Research, 21,
319-328.[ PubMed]
Hayhoe, M., Benimoff, N. I.,
& Hood, D. C. (1987). The time-course of multiplicative and subtractive
adaptation processes. Vision Research,
27, 1981-1996.[ PubMed]
Hood, D. C., Ilves, T., Maurer,
E., Wandell, B., & Buckingham, E. (1978). Human cone saturation as a
function of ambient intensity: A test of models of shifts in the dynamic range.
Vision Research, 18, 983-993.[ PubMed]
Kaplan, E., & Benardete,
E. (2001). The dynamics of primate retinal ganglion cells.
Progress in Brain Research, 134,
17-34.[ PubMed]
Kaplan, E., & Shapley, R.
M. (1986). The primate retina contains two types of ganglion cells, with high
and low contrast sensitivity. Proceedings of
the National Academy of Sciences, USA, 83, 2755-2757.[ PubMed]
Lee, B. B., Pokorny, J., Smith,
V. C., & Kremers, J. (1994). Responses to pulses and sinusoids in macaque
ganglion cells. Vision Research, 34,
3081-3096.[ PubMed]
Lee, B. B., Pokorny, J., Smith,
V. C., Martin, P. R., & Valberg, A. (1990). Luminance and chromatic
modulation sensitivity of macaque ganglion cells and human observers.
Journal of the Optical Society of America A,
7, 2223-2236.[ PubMed]
Lee, B. B., Smith, V. C., &
Pokorny, J. (1999). Macaque ganglion cell responsivity on sinusoidally modulated
backgrounds [Abstract]. Investigative
Ophthalmology and Visual Science, 40, S817.
Pokorny, J., & Smith, V.
C. (1997). Psychophysical signatures associated with magnocellular and
parvocellular pathway contrast gain. Journal
of the Optical Society of America A, 14, 2477-2486.[ PubMed]
Shapley, R. M., &
Victor, J. D. (1978). The effect of contrast on the transfer properties of cat
ganglion cells. Journal of Physiology, London,
285, 275-298.[ PubMed]
Shapley, R. M., &
Victor, J. D. (1979). Nonlinear spatial summation and the contrast gain control
of cat retinal ganglion cells. Journal of
Physiology, 290, 141-161.[ PubMed]
Sharpe, L. T., &
Wyszecki, G. (1976). Proximity factor in color-difference evaluations.
Journal of the Optical Society of America,
66, 40-49.[ PubMed]
Smith, V. C., Sun, V. C.,
& Pokorny, J. (2001). Pulse and steady-pedestal contrast discrimination:
effect of spatial parameters. Vision Research,
41, 2079-2088.[ PubMed]
Victor, J. D. (1987). The
dynamics of the cat retinal X-cell centre.
Journal of Physiology, 386, 219-246.[ PubMed]
Victor, J. D. (1988). The
dynamics of the cat retinal Y cell subunit.
Journal of Physiology (London), 405,
289-320.[ PubMed]
|
|